roof opens and closes both halves simultaneously - with a small glitch, but this is already fixed and will be hopefully fully tested tomorrow
detection of emergency situations (e.g. timeouts) added to roof software and works as expected
auto-activation sequence (switch from standby to auto) works as expected
we hit overheat of the motors, both halves fall ~ 30 cm to opening supports (it looks that when motor overheats, clutch is released as well). No damage occurs and all motors operates properly after cold-down period
telescope driver fixed and operates almost perfectly
images are written to database
cloudsensor setpoints set (to 9 and 10), cloud sensor now have control over weather decisions
various updates and small fixes among code
fixed IP ordered, most probably that is why ADSL stop working properly. I will ask Phil tomorrow.