Telescope referencing

Aug 27nd: Telescope is know to not reference if on clokwise end. The solution is:

telnet tel 65432
1 set az.power=0

then gently turn in AZ axis counter-clokwise (eg. starting with camera facing valley, move towards Veleta and then OSN building). The end switch is located bellow telescope, see this image:

Gently move telescope in AZ axis till you hit the end.

Then

telnet tel 65432
1 set az.power=1

And it should reference in AZ axis.

Setting dome parking position

Dome park position can be set only locally on dome control box. The box has eight small buttons and five line of LCD display. First, switch box to remote mode by turning key clokwise. Then press simultaneusly left and right top buttons. System will enter technical mode, where you can change various parameters. Using right and left top buttons, move to screen 3 (axis 0). Using bottom buttons, move cursor to park position which is a few lines bellow initial display. Using middle two buttons, change park value. Move a line down to confirm value and see that system accept it.

To save park position, so it will be remembered after power cycling of the dome control box, go to screen 18 and set Save params to 1. Move line down/up, you will get **Written 83..“ message on screen, which will disapear after while.