-====== How to run observation manually ====== 
- 
-This text describes how to get rid of selector and present to system own ideas about target which shall be selected. 
- 
-  - run **rts2-mon** 
-  - Change to //SEL// entry (selector) using keys up/ keys down 
-  - Press tab to move to selector 
-  - Key down to move highlighted row to //selector_enabled// 
-  - Enter, select **false**, enter to confirm 
-  - Tab key twice to move back to device list 
-  - Keys up/down to move to //EXEC// - executor component 
-  - Then you can: 
-    * Queue next target using //next <target_id>// command, so if you would like to queue target 1001, write //next 1001// and hit enter. You will see next target in executor 
-    * Schedule quick observation by issuing //now <target_id>// command. 
-  - After you finish with manual run, do not forget to switch system back to autonomous mode. 
- 
- 
- 
- 
  