hw:zelio [2009/06/17 12:23] pkubanekhw:zelio [2010/05/10 18:33] – Added SR3NET01BD link pkubanek
Line 8: Line 8:
 The programme is designed for clam shell type roof with two halfs opening and The programme is designed for clam shell type roof with two halfs opening and
 closing, four end -of-path sensors and two motors. If your needs are different, closing, four end -of-path sensors and two motors. If your needs are different,
-please either help yourself or contact Petr Kubanek with questions.+please either help yourself or contact Petr Kubanek with questions. PLC has attached Ethernet modbus output - [[http://www.schneider-electric.com/sites/corporate/en/products-services/automation-control/products-offer/range-presentation.page?c_filepath=/templatedata/Offer_Presentation/3_Range_Datasheet/data/en/shared/automation_and_control/zelio_logic.xml#|SR3NET01BD]], which is used for PC-PLC communication. Please see description of registers at the end of the page.
  
 There is a picture of front panel. In our experiences, nothing beats hardware switches when it comes to reliably block roof opening by staff, including not-so-computer maniacs. Cost of the switches, cables and box was about 1000 ZAR ~ 95 EUR. Cost of electronics inside (Zelio, ..) was about 500 EUR. There is a picture of front panel. In our experiences, nothing beats hardware switches when it comes to reliably block roof opening by staff, including not-so-computer maniacs. Cost of the switches, cables and box was about 1000 ZAR ~ 95 EUR. Cost of electronics inside (Zelio, ..) was about 500 EUR.
hw/zelio.txt · Last modified: 2020/09/28 23:30 by pkubanek