howto:running_observation_manually [2008/09/10 15:10] – Described how to run observation manually pkubanek
Line 1: Line 1:
 +====== How to run observation manually ======
 +
 +This text describes how to get rid of selector and present to system own ideas about target which shall be selected.
 +
 +  - run **rts2-mon**
 +  - Change to //SEL// entry (selector) using keys up/ keys down
 +  - Press tab to move to selector
 +  - Key down to move highlighted row to //selector_enabled//
 +  - Enter, select **false**, enter to confirm
 +  - Tab key twice to move back to device list
 +  - Keys up/down to move to //EXEC// - executor component
 +  - Then you can:
 +    * Queue next target using //next <target_id>// command, so if you would like to queue target 1001, write //next 1001// and hit enter. You will see next target in executor
 +    * Schedule quick observation by issuing //now <target_id>// command.
 +  - After you finish with manual run, do not forget to switch system back to autonomous mode.
 +
 +
 +
 +
  